1、电缆的包装需要使用电缆盘,有铁盘、木盘和铁框木盘,盘的外径对运输、保管的成本影响较大,用于10kV及以下电缆的盘径以3.2米以下为宜,盘宽以不超过2.2米为好,对于超过3.5米的要用特殊的运输车。
1, the cable package requires the use of cable tray, iron plate, wooden frame and wooden plate impact diameter on transportation and storage cost is bigger for 10kV and below the cable diameter of disc to below 3.2 meters is appropriate, with no more than 2.2 meters wide as well, for more than 3.5 meters with special special transport vehicle.JFEYH10KV高压电机引接线 特种电机引接线
2、每盘电缆的重量与电缆的规格型号和长度有关,一般中低压电缆单盘长度在500米左右,重量在3-10吨。JFEYH10KV高压电机引接线 特种电机引接线
2, the weight of each cable is related to the specification, type and length of the cable. The length of the single disk of the medium and low voltage cable is about 500 meters, and the weight is 3-10 tons.
3、在运输装卸过程中,不应使电缆及电缆盘受到损伤。严禁将电缆盘直接由车上推下。电缆盘不应平放运输、平放贮存。
3. The cable and cable tray should not be damaged during transportation and loading and unloading. It is forbidden to push the cable tray directly from the car. The cable tray should not be laid down and stored horizontally.
4、运输或滚动电缆盘前,必须保证电缆盘牢固,电缆绕紧。滚动时必须顺着电缆盘上的箭头指示或电缆的缠紧方向。
4. Before transporting or rolling the cable tray, it is necessary to ensure that the cable plate is firm and the cable is tight. When rolling, it is necessary to follow the arrow instructions on the cable plate or the direction of the cable.
5、电缆在运输、保管中封头应进行保护,可靠密封,防止受潮进水。当外观检查有怀疑时,应进行受潮判断或试验。保管中封头有损坏应立即处理。JFEYH10KV高压电机引接线 特种电机引接线
5, the cable in transportation, storage head should be protected, reliable sealing, to prevent damp water. When the appearance inspection is doubtful, the damp judgement or test should be carried out. The damage of the seal head in the storage should be dealt with immediately.
6、电缆保管应集中分类存放,并应标明型号、电压、规格、长度。电缆盘之间应有通道。地基应坚实,当受条件限制时,盘下应加垫,存放处不得积水。当电缆盘有损坏时,应及时更换。
6. The storage of cable should be centralized and classified, and the model, voltage, specification and length should be marked. There should be a channel between the cable trays. The foundation should be solid, when the condition is limited, the cushion should be added, and the storage area should not be flooded. When the cable tray is damaged, it should be replaced in time.
7、充油电缆在运输、保管中应保持压力油箱、油管、阀门和压力表完好。保管期应经常检查油压,并作记录,油压不得降至最低值。当油压降至零或出现真空时,应及时处理。
7, the oil filled cable in transportation, storage should keep the pressure tank, tubing, valve and pressure gauge intact. The storage period should be regularly checked and recorded and the oil pressure should not be reduced to the minimum. When the oil pressure drops to zero or the vacuum occurs, it should be dealt with promptly.